News
Articles
Case Histories
Buyer's Guide
Career Center
June 2008
May 2008
Arsenic
Bottled Water
Disinfection
Membrane Filtration
Click here for a subscription to
Water Quality Products
Give us your feedback on our site.
Change your subscription info
Subscribe to our
WQP/WWD Executive News Summary e-Newsletter.
Sponsored by Water Quality Products (WQP)


LEARNMORE!
RSS: WQP Articles

 Related Articles
"RO Maintenance"

 Editorial Categories
  • Infrastructure Security
  • Infrastructure Security
  • Maintenance
  • Maintenance
  • Membranes
  • Membranes / Separations
  • Reverse Osmosis
  • Reverse Osmosis

     Share It
    "/popup_app/index.cfm?fuseaction=showEmailPageToAFriendForm&appDirectory=wqp&linkQueryString=fuseaction=showArticle*amp*articleID=524&linkLabel=Changing Reverse Osmosis Membranes" target="_new">   "/popup_app/index.cfm?fuseaction=showEmailPageToAFriendForm&appDirectory=wqp&linkQueryString=fuseaction=showArticle*amp*articleID=524&linkLabel=Changing Reverse Osmosis Membranes" target="_new">Email this Article to a Friend

    Changing Reverse Osmosis Membranes

       Terms & Conditions of Use


    Changing membranes in pressure vessels is easy with the proper tools

    - Dorothy Korszen, P.E.
    Changing membranes in pressure vessels is easy with the proper tools. Here is how we do it.

    To open a PVC pressure vessel, first remove any pins holding one end plug in place. (Note: many fiberglass pressure vessels use a snap ring to hold the plug in place. Properly -sized snap ring pliers should be used to safely remove the snap ring.) Next, remove the fittings from the plug.

    Thread a nipple and tee into the feed or concentrate port long enough to extend past the end of the pressure vessel. Apply a coating of glycerin to the inside and rim of the pressure vessel from the plug to the end so the plug will slide out more easily. Pry off the plug using a pry bar. We either use a ball joint separator, also called a "pickle fork," which is an automotive tool, or a slide hammer. Remove the fittings used to remove the plug.

    Next, remove the membrane from the pressure vessel, noting which side the brine seal is on. Insert the new membrane with the brine seal on the feed side of the pressure vessel. Replace any damaged O-rings. Lubricate the plug with glycerin. Tap the plug securely into place using a piece of wood and a rubber mallet. Replace any pins to hold the plug in place. Reattach the fittings to the pin.

    With a new membrane, flush all permeate and concentrate to drain for 30 minutes at low pressure to flush out the preservative.




    Dorothy Korszen, P.E., J.D., is the executive vice president of Environmental Products USA, Inc., a manufacturer of membrane systems and pressure vessels.

    Source: Water Quality Products   October 1996