News
Articles
Case Histories
Buyer's Guide
Career Center
April 2011
August 2011
Dealer Insight - September 2011
Dealer Insight April 2011
Dealer Insight August 2011
Dealer Insight February 2011
Dealer Insight January 2011
Dealer Insight July 2011
Dealer Insight June 2011
Dealer Insight March 2011
Dealer Insight May 2011
December 2011
eNews - December 2011
eNews - February 2012
eNews - January 2012
eNews - November 2011
eNews - October 2011
February 2011
February 2012
January 2011
January 2012
July 2011
June 2011
March 2011
May 2011
November 2011
October 2011
September 2011
Arsenic
Bottled Water
Disinfection
Membrane Filtration
Click here for a subscription to
Water Quality Products
Give us your feedback on our site.
Change your subscription info
Subscribe to our
WQP/WWD Executive News Summary e-Newsletter.
Sponsored by Water Quality Products (WQP)


LEARNMORE!
RSS: WQP Articles

 Related Articles
"Commercial & Industrial Pretreatment"

"Expanding the Toolbox"

"Extending the Life of Your Membranes"

"Hawaii-RO"

"Movin’ On Up"

"POE Ultrafiltration Surges Ahead"

"Pretreatment for Portable Purification"

"Testing for Better System Efficiency"

"Under the Sea"

 Editorial Categories
  • Membranes / Separations
  • Reverse Osmosis
  • Ultrafiltration

     Related Links
  • Dow Water & Process Solutions

     Alternate Format
    View article as a PDF
     Share It
    "/popup_app/index.cfm?fuseaction=showEmailPageToAFriendForm&appDirectory=wqp&linkQueryString=fuseaction=showArticle*amp*articleID=10900&linkLabel=Performing with Pretreatment" target="_new">   "/popup_app/index.cfm?fuseaction=showEmailPageToAFriendForm&appDirectory=wqp&linkQueryString=fuseaction=showArticle*amp*articleID=10900&linkLabel=Performing with Pretreatment" target="_new">Email this Article to a Friend

    Share |

    Performing with Pretreatment

       Terms & Conditions of Use


    UF pretreatment enables optimal RO processes

    - By Eric Shao

    Related search terms from www.waterinfolink.com: membranes, reverse osmosis, ultrafiltration

    Industries with large demand for process water often rely on reverse osmosis (RO) water treatment units for safe and predictable operation. RO continuously provides process water at a high level of quality and a comparably low cost. RO systems, however, are delicate and require sufficient pretreatment of the feedwater to prevent membrane fouling.

    Pretreatment is especially important when the feedwater is located in challenging conditions such as those encountered at the NingBo Jiufeng Co-gen, Ltd. Co. (Jiufeng) plant in China. The designers of the plant chose an economic ultrafiltration (UF) pretreatment solution for their RO unit. Since the start-up of the facility in August 2005, the Jiufeng plant has run with stable performance, resulting in equally good performance of the RO system.

    Challenging Feed Water

    Jiufeng participates in many public sectors, including heat and electricity development. The first-phase heat and electricity production site handles the generation, installation and repair of electrical services for the entire NingBo province. The site also maintains a steady supply of steam and hot water throughout the province with its 270-ton-per-hour production capacity.

    The planned expansion to a second site will result in doubling the existing heat-generation capacity. Jiufeng uses the nearby XiePu River as source water for the factory’s water treatment plants, one of which produces boiler make-up water. Because the intake of the plant is close to the estuary, which causes seasonal, tidal and weather-related seawater intrusion into the river, the water treatment plant of Jiufeng is supplied with water of constantly changing salt content, turbidity and temperature. The average content of the river water is total suspended solids of 134.5 mg/L and total iron of 0.3 mg/L. In addition, the temperature can range from 64°F to 77°F on any given day.

    “One of the biggest challenges that customers, such as Jiufeng, face is finding an economical solution that is able to handle variable swings in dissolved solids and feedwater conditions while removing turbidity to a very low level without the addition of pretreatment prior to the utlrafiltration system,” said Christina Fang, area commercial development manager for Dow Water Solutions. “Our ultrafiltration modules provide steady performance, making the membranes a reliable, economical and efficient solution for the NingBo site.”

    Economic Solution

    With these tough conditions in mind, plant designers were looking for an economically viable solution for their water pretreatment unit. Their top choices were conventional filters or a pretreatment method using UF membranes.

    The relatively small SFP-2660 UF modules appealed to the Jiufeng designers in regards to both performance and capital cost requirements. The module, with a length of 60 in., offers higher efficiencies over a wider range of feedwater conditions compared to some modules that are longer in length.

    The unplasticized polyvinylchloride (U-PVC) housing eliminates the need for costly pressure vessels and the 6-in. diameter allows for a compact design in space-constrained installations. The outside-in flow configuration of its hydrophilic double-walled hollow fibers with 0.03-μm nominal pore diameter enables cleaning through simple backwashing and air scouring to remove the fouling layer. The double-walled hollow fibers also help reduce the need for additional pretreatment processes.

    The 288 UF modules installed at Jiufeng are, therefore, as sufficient as the sole pretreatment process for the feedwater of the RO unit.

    Pretreatment Performance

    The performance of the pretreatment unit has been satisfactory since start-up in August 2005. The product water turbidity is on average 0.1 nephelometric turbidity units (NTU), at less than 0.2 NTU 90% of the time. The silt density index (SDI) has remained at less than 2. In addition, not a single chemically enhanced backwash has been needed since the start-up.

    Once every six months, a clean-in-place (CIP) is needed by Jiufeng to restore the initial performance of the UF membranes. The transmembrane pressure (TMP) dropped down to less than approximately 5 psi immediately after each CIP, and remained relatively constant over the following six months. The flow pressure index, calculated as the skid’s permeate flow (m3/h) divided by TMP (bar), was restored to its initial value after each CIP, showing the reliability and cleanability of the UF modules. This is largely due to the high strength and chemical resistance of its PVDF polymeric fibers, allowing longer UF membrane life.

    The UF pretreatment at Jiufeng has provided high-quality RO feedwater, enabling optimal flux and high recovery operation of the installed Filmtec BW30-400 membranes. So far, only four cleanings of the RO membranes have been necessary, allowing UF as the sole pretreatment at Jiufeng to not only provide feedwater of constant high quality without showing signs of weakening over time, but also helping operate the RO unit at lower cost due to less downtime of the unit and a decreased demand for costly cleaning chemicals.

    In addition, less cleaning helps prolong the lifespan of the RO membranes, reducing the need for replacement and reducing capital costs. Jiufeng is a solid example of how using UF pretreatment for RO membranes is an economically viable and sustainable solution for industries with large process water demand, even when the supply water is of challenging conditions and the need for a reduced footprint is key.




    Eric Shao is marketing development specialist for Dow Water & Process Solutions. Shao can be reached by e-mail at shao3@dow.com.

    Source: Water Quality Products   July 2009   Volume: 14 Number: 7