Measurement Technologies, Inc.

Measurement Technologies manufacturers The H2O Neutralizer, a dechlorination/chlorination device and markets related accessory equipment as well as being a supplier of No-Chlor Calcium Thiosulfate & Ascorbic Acid (dechlorination grade). The H2O Neutralizer will dechlorinate discharge flows as low as 10 gpm and with as little as 5-psi. The 3M device has neutralized over 600 ppm of chlorine. Chlorination can be done with service lines of 1" or larger.

Address

P.O. Box 2195
Redmond, Washington 98073-2195
United States
Phone: 425-836-8683
Fax: 425-484-6664

Product Categories

Siemens Water Technologies

Siemens Water Technologies is the world’s leading water and wastewater treatment company. We provide the most comprehensive, cost-effective and reliable treatment systems and services for reclamation and reuse of water for our industrial, institutional, commercial and municipal customers. With the broadest range of technologies, a nationwide service network and a long history of innovation and leadership in the water treatment market, Siemens Water Technologies offers everything from emergency water supply and conventional treatment processes to high-tech membrane filtration systems. Our innovations combine treatment processes into smaller, more efficient treatment packages.

Address

181 Thorn Hill Road
Warrendale, PA 15086
USA
Phone: 800-525-0658
Fax: 724-772-1322

Product Categories

Chlorinators Incorporated

The REGAL gas chlorinator is used all over the world to disinfect and purify municipal drinking water and wastewater, industrial wastewater, and more. The REGAL gas chlorinator provides a consistent chlorine residual, eliminating a lot of guesswork. REGAL is safe and strong with a simple design. The all-vacuum system virtually eliminates the possibility of gas leaks. REGAL is directly mounted with the strongest yoke in industry. In addition, it has an extremely tough and resilient diaphragm and is made with corrosion-resistant materials. The chlorinator is carefully assembled by hand, and tested by skilled technicians. With only 68 parts, REGAL is very easy to maintain and clean.

Address

1044 S.E. Dixie Cutoff Road
Stuart, Florida 34994-3436
USA
Phone: 772-288-4854
Fax: 772-287-3238

Product Categories

KDF Fluid Treatment, Inc.

KDF PROCESS MEDIA - Protect or Replace existing filters, founded in 1984, KDF Fluid Treatment, Inc. is a technological leader in the fluid treatment industry. Beginning with a U.S. patent for KDF redox alloy media in 1987, the company continues its technological innovation. KDF process media are used in pre-treatment, primary treatment, and wastewater applications. KDF media supplement or replace existing technologies to dramatically extend system life, lower total cost, and decrease maintenance. Patented KDF process media are 100 percent recyclable and contain no chemical additives.

Address

Three Rivers Area Enterprise Park
Three Rivers, MI 49093
Phone: 800-437-2745 /, ext. 24
Fax: 269-273-4400/8

Product Categories

Blue-White Industries

BLUE-WHITE manufactures peristaltic and diaphragm metering pumps designed specifically for treatment of water and wastewater plus,Hybrid Ultrasonic Flowmeters; Variable Area Flowmeters; and Digital Paddlewheel Meters. All Blue-White Peristaltic pumps have built-in patented Tube Failure Detection Systems. Two series are offered - for lower output requirement apps choose FLEXFLO. For high output requirements choose Flex-Pro. Well priced Variable Area Flowmeters for in-line or panel mount installation in a wide range of calibrations and materials. Options include integral adjustment valves. SonicPro Ultrasonic meters with Non invasive clamp-on transducers. BW DIGI-METER Paddlewheel Meters have precise digital technology and re offered in a wide range of mounting styles.

Address

5300 Business DR
Huntington Beach, California 92649
Phone: 714-893-8529
Fax: 714-894-9492

Product Categories

Ultraviolet Dechlorination Technology

At the Procter & Gamble manufacturing plant in Greensboro, N.C., an Aquionics ultraviolet (UV) dechlorination unit was installed before two banks of reverse osmosis (RO) membranes. Trials that ran soon after the UV system’s installation showed a dramatic reduction in the RO membrane wash frequency—down from an average of eight cleanings per month to only two per month.

Deck: 

Reverse Osmosis Membranes Maintenance Costs Reduced

About The Author: 

Aquionics offers more than 20 years experience in the manufacture, application and development of UV equipment for progressive, nonchemical disinfection and contamination control. For more information, call 800-925-0440; www.aquionics.com.

Activation Date: 
June 26, 2002
Issue Reference: 
Legacy
Legacy ID: 
13172